Description

The Series CDTA Communicating Carbon Dioxide Detectors combine the function of three room sensors into a single, compact housing. Parameters include carbon dioxide, humidity, temperature, and temperature set point with override. A 4-wire connection and daisy chaining together reduces installation cost. The RS-485 MAC address is set up using on board DIP switches. Additional DIP switches are used to select Modbus RTU or BACnet MS/TP and to limit access to the set up menu. The barometric pressure can be programmed to correct for altitude. The humidity sensor is field replaceable without the need for additional calibration. Optional integral and remote displays are available to display temperature, humidity, or temperature set point instead of CO2.

Product Specifications

Name Value
Application Air Quality, Carbon Dioxide Transmitters
Category Dwyer
Display name 1 Catalog Page
Display name 2 Data Sheet
Features and benefits Application: Demand Control Ventilation in Schools, Office Buildings, Hospitals, and Other Indoor Environments, LEED Certification | Easily Installation with Optional Remote Display Tool and Simple Installation with Backplate Electrical Connection | Sensor (CO2): NDIR, 15 Year Life Expectancy; Humidity: Capacitive Polymer; Temperature: Solid State Band Gap | Requires Minimal Maintenance with Automatic Baseline Correction (ABC) to Account for Sensor Drift | Range: CO2 : 0 to 2000 or 5000 PPM CO 2 (Depending on Model); Humidity: 0 to 100 Percentage RH; Temperature: 32 to 122 deg F (0 to 50 deg C) | Reduces the Number of Devices Mounted in the Space with Integral Humidity and Temperature Sensors | Prevent Tampering with Physical Hardware Lockout | Reduce Installation Time with Field Selectable Modbus and BACnet Communications | Accuracy: CO 2 : ±40 PPM ±3 Percentage of Reading 2000 PPM; ±50 PPM + 5 Percentage of Reading 5000 PPM; RH: ±2 Percentage (10 to 90 Percentage RH); Temperature: ±1 deg C @ 25 deg C
P21 delete flag false
Product category Temperature Sensors & Transmitters
Product subcategory Room
Restricted class id NULL
Restricted item false
Series Dwyer
Short desc Dwyer Carbon Dioxide/Temperature/Humidity Communicating Stat with Set Point and Override, Modbus and BACnet Output, North American Wall Mount Housing, 5000 ppm Range, LCD Display CDTA-5N000-LCD
Supplier part number CDTA-5N000-LCD
Ultra store sync us Yes
Vendor active Y
Vendor enabled true

Features and Benefits

Application: Demand Control Ventilation in Schools, Office Buildings, Hospitals, and Other Indoor Environments, LEED Certification | Easily Installation with Optional Remote Display Tool and Simple Installation with Backplate Electrical Connection | Sensor (CO2): NDIR, 15 Year Life Expectancy; Humidity: Capacitive Polymer; Temperature: Solid State Band Gap | Requires Minimal Maintenance with Automatic Baseline Correction (ABC) to Account for Sensor Drift | Range: CO2 : 0 to 2000 or 5000 PPM CO 2 (Depending on Model); Humidity: 0 to 100 Percentage RH; Temperature: 32 to 122 deg F (0 to 50 deg C) | Reduces the Number of Devices Mounted in the Space with Integral Humidity and Temperature Sensors | Prevent Tampering with Physical Hardware Lockout | Reduce Installation Time with Field Selectable Modbus and BACnet Communications | Accuracy: CO 2 : ±40 PPM ±3 Percentage of Reading 2000 PPM; ±50 PPM + 5 Percentage of Reading 5000 PPM; RH: ±2 Percentage (10 to 90 Percentage RH); Temperature: ±1 deg C @ 25 deg C

    Your Local Branch

    Enter your ZIP code to show local inventory.
    View Map

    Austin

    9705 Burnet Road, Suite 312
    Austin, TX 78758
    (512) 612-9233
    Set As My Branch

    Boston

    30 Vineland St
    Brighton, MA 02135
    (617) 206-3737
    Set As My Branch

    Charlotte

    9800 Southern Pine Blvd. Suite N.
    Charlotte, NC 28273
    (980) 397-0455
    Set As My Branch

    Dallas

    2241 Valwood Parkway, Suite 200
    Farmers Branch, TX 75234
    (214) 390-2201
    Set As My Branch

    Houston

    1434 W Sam Houston Pkwy N, #190
    Houston, TX 77043
    (281) 744-4356
    Set As My Branch

    Milwaukee

    11250 West Lapham St
    West Allis, WI 53214
    (414) 455-0562
    Set As My Branch

    Minneapolis

    3340 Gorham Ave
    Minneapolis, MN 55426
    (952) 388-2221
    Set As My Branch

    Nashville

    820 Fesslers Parkway
    Nashville, TN 37210
    (615) 258-7474
    Set As My Branch

    New Jersey

    1095 Cranbury South River Rd STE 1
    Jamesburg, NJ 08831
    (201) 377-2333
    Set As My Branch

    New Orleans

    5401 Jefferson Hwy, Suite G
    Harahan, LA 70123
    (504) 576-0556
    Set As My Branch

    New York

    233 West 29th Street
    New York, NY 10001
    (212) 488-0229
    Set As My Branch

    Phoenix

    1555 W University Dr Ste 106
    Tempe, AZ 85281
    (480) 682-5966
    Set As My Branch

    Salt Lake City

    3186 South Washington Street
    Salt Lake City, UT 84115
    (385) 355-6659
    Set As My Branch

    San Antonio

    11906 Warfield
    San Antonio, TX 78216
    (210) 874-7202
    Set As My Branch

    San Diego

    12700 Stowe Drive, Suite 100
    Poway, CA 92064
    (858) 263-0523
    Set As My Branch