Multiprotocol Module with a MIX of I/O's - the Ultimate Controller Extension - The most versatile I/O module with 38 inputs and outputs, offering the most cost-effective price per point ratio. Powerful I/O module that works as a remote or distributed I/O over IP with open protocols: BACnet IP, and Modbus TCP/IP. Open protocols standard offers the versatility of installing the modules in both new and existing facilities, whether it is a system expansion or a retrofit. The most popular types of inputs and outputs are Mixed in a space-saving design and allow the module to be a versatile controller extension, whether in a small or large facility. 8 Universal Inputs - Support for over 20 types of temperature sensors and voltage, resistance, current, and dry contact measurements on each universal input. 12 Digital Inputs - Dry contact inputs - made for monitoring. 100 Hz fast pulse counter with override function saves the real-time values to the EEPROM memory. 12 Digital Outputs - Digital outputs equipped with normally open 3 A relays allow for direct control without additional relays. 6 Analog Outputs - 0-10 VDC control with 10 mA accuracy, PWM modes, and a maximum load of up to 20 mA to power external relays makes the output suitable for a variety of scenarios. Modbus TCP/IP to Modbus RTU/ASCII Gateway - Built-in Modbus gateway on the COM1 port enables integration of up to 128 Modbus slave devices to the IP layer. Simplified Configuration and Commissioning Process - The module allows for seamless configuration over BACnet, Modbus, built-in web server, or dedicated free of charge tool. The ability to be powered from a USB port facilitates local testing and a straightforward updating process. Two Ethernet ports working in a switch mode allow for daisy chaining of multiple modules over the RJ45, which facilitates the cabling process and reduces engineering time. Quality and Reliability Confirmed by Certificate - iSMA CONTROLLI is a long-standing member of the BACnet commun
Features & Benefits
2 Ethernet Interface with Built-in Switch, RS485 Interface, Mini USB Type B Interface, Status LED Indicators, DIN Rail Mounted, 38 I/Os On Board
Temperature Input in Celsius Degrees - 10K3A1, 10K4A1, Carel 10K, 20K6A1, 2.2K3A1, 3K3A1, 30K6A1, SIE1, TAC1, SAT1, Pt1000, Ni1000 0C, Ni 1000 20C, Ni1000 LG 2, Temperature Input in Fahrenheit Degrees - 10K Type2, 10K type3, 20K, 3K, PT 1000, Ni 1000 32F, Ni 1000 70F, Resistive Input - 0-1000 kOhm, Voltage Input - 0-10 VDC, Current Input - 0-20 mA, Dry Contact Input
Output 0-10 VDC Maximum Load Up to 20 mA, PWM - 0.01 Hz, 0.1 Hz, 1 Hz, 10 Hz, 100 Hz
NO Relay Output, Resistive Load Max. 3 A at 230 VAC/30 VDC, Inductive Load Max. 75 VA at 230 VAC/30 W at 30 VDC
Dry Contact Inputs, Fast Pulse Counter Up to 100 Hz Save in EEPROM Memory